New PDF release: Antifreeze Solutions in Home Fire Sprinkler Systems

By Code Consultants Inc.

ISBN-10: 146143839X

ISBN-13: 9781461438397

ISBN-10: 1461438403

ISBN-13: 9781461438403

Antifreeze ideas in domestic fireplace Sprinkler platforms examines the use of antifreeze recommendations in residential sprinklers, and analyzes their effectiveness in controlling a hearth and assisting in containment. The publication additionally investigates the potential of a large-scale ignition happening from recommendations of various combinations, and proposes the optimum ones for lowering flammability. 

Antifreeze options in domestic fireplace Sprinkler structures is designed for practitioners as a reference advisor for dealing with antifreeze recommendations in residential sprinkler platforms. Researchers operating in a similar box also will locate the booklet valuable.

Show description

Read Online or Download Antifreeze Solutions in Home Fire Sprinkler Systems PDF

Similar quality control books

Download e-book for kindle: Patterns of Problem Solving (2nd Edition) by Moshe F. Rubinstein

Explores the ideas and strategies of challenge fixing. The textual content examines qualitative instruments, quantitative instruments, and human values - and their function within the challenge fixing approach.

Download e-book for iPad: Network Reliability and Resilience by Ilya Gertsbakh, Yoseph Shpungin

This publication is dedicated to the probabilistic description of a community within the means of its destruction, i. e. elimination of its parts (links, nodes) showing because of technical mess ups, typical failures or intentional assaults . it's eager about a pragmatic method of community reliability, in accordance with software of Monte Carlo method to numerical assessment of community most crucial structural parameters.

New PDF release: Reliability Evaluation of Engineering Systems: Concepts and

Based on new advancements within the box, sensible instructing adventure, and readers' feedback, the authors of the warmly acquired Reliablity overview of Engineering structures have up-to-date and prolonged the work-providing prolonged assurance of fault bushes and a extra entire exam of likelihood distribution, between different things-without annoying the original's proposal, constitution, or type.

Get FMEA - Einführung und Moderation: Durch systematische PDF

Dieses Buch hilft Ihnen, die Methodik FMEA sowie die angrenzenden Themen zu verstehen und anzuwenden. Es räumt mit dem Vorurteil auf, FMEA wäre „nur“ ein Qualitätstool, das von Qualitätsspezialisten durchgeführt wird. Vielmehr kann die FMEA in jeder Branche als Werkzeug benutzt werden, um Produkte, Projekte, Aufgaben und Dienstleistungen äußerst planbar, nachvollziehbar und zielorientiert umzusetzen.

Extra resources for Antifreeze Solutions in Home Fire Sprinkler Systems

Example text

9 Concealed Sprinkler 40% Propylene Glycol 50% Glycerin 45% Propylene Glycol 55% Glycerin 50% Propylene Glycol 7,000 6,000 5,000 4,000 3,000 2,000 1,000 0 0 10 20 30 40 50 60 70 -1,000 -2,000 Sprinkler Flow Rate (gpm) Fig. 15 Increase in fire size for various antifreeze solutions The results presented above show increases in heat release rate of more than 6,000 kW or 500% for the 50% propylene glycol and 55% glycerin solutions at certain flow rates. This is due in large part to ignition of the antifreeze spray extending away from the initial fire condition.

National Fire Protection Association, NFPA 13: Automatic Sprinkler Systems Handbook, J. D. Lake, Ed. Quincy, MA, 2010. 3. , “Literature Review and Research Plan, Antifreeze Solutions in Home Fire Sprinkler Systems,” 2010. 4. , “Fire Test Data Summary for Residential Sprinklers Discharging Antifreeze Solutions,” Northbrook, 2010. 5. National Fire Protection Association, NFPA 13, Standard for the Installation of Sprinkler Systems. Quincy, MA: National Fire Protection Association, 2010. 6. National Fire Protection Association, Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes.

15, below, which shows the increase in heat release rate due to the application of each antifreeze solution using the same sprinkler and ignition source. 9 Concealed Sprinkler 40% Propylene Glycol 50% Glycerin 45% Propylene Glycol 55% Glycerin 50% Propylene Glycol 7,000 6,000 5,000 4,000 3,000 2,000 1,000 0 0 10 20 30 40 50 60 70 -1,000 -2,000 Sprinkler Flow Rate (gpm) Fig. 15 Increase in fire size for various antifreeze solutions The results presented above show increases in heat release rate of more than 6,000 kW or 500% for the 50% propylene glycol and 55% glycerin solutions at certain flow rates.

Download PDF sample

Antifreeze Solutions in Home Fire Sprinkler Systems by Code Consultants Inc.


by Brian
4.2

Rated 4.27 of 5 – based on 20 votes